200 East End Avenue

Project Highlights

Project Highlights

The board at 200 East End Avenue wanted to lower operating costs and improve tenant comfort by targeting areas of energy and water waste. They sought to obtain NYSERDA Multifamily Performance Program funding to cover the costs of completing an energy audit as well as project implementation. Working with the board, Bright Power performed the energy audit, identified savings opportunities, assisted with installation, and secured NYSERDA incentives.

Market Type

Multifamily Cooperative

Location

New York, NY

Owner

200 East End Avenue Board

$317,000

1st year cost savings

45%

1st year energy usage reduction

$166,000

NYSERDA incentives

Work Completed

Work Completed

  • Installed new heat exchanger for domestic hot water, 200-gallon hot water storage tank, and electronic mixing valve
  • Installed a single 100-HP condensing hydronic heating boiler, eliminating the use of steam for heating, cooling, and domestic hot water generation
  • Replaced steam-driven, single stage absorption chiller with two natural gas-fired two stage 200-ton absorption chillers
  • Replaced T12 fixtures with magnetic ballasts in parking garage, common area, and mechanical room with T8 fixtures with electronic ballasts
  • Installed bi-level lighting in the stairwells as well as occupancy sensors in relevant areas
  • Trained building staff on proper maintenance techniques and how to operate new equipment
  • Replaced fans and motors in the existing cooling tower with high-efficiency units